Part Number
Definition:
A RIGID OR FLEXIBLE TUBING HAVING UNIFORM INSIDE AND OUTSIDE DIAMETERS IN THE OVERALL LENGTH. IT IS SPECIFICALLY DESIGNED TO PREVENT ANY UNDESIRABLE FLOW OF CURRENT BETWEEN CONDUCTORS AND OTHER OBJECTS. INCLUDES SHRINKABLE TYPE TUBING, ITEMS IN BULK AND IN SPECIFIC FABRICATED LENGTHS (CUT TO SIZE). EXCLUDES ITEMS NOT HAVING RATED ELECTRICAL CHARACTERISTICS. ALSO EXCLUDES BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; CONDUIT (AS MODIFIED); INSULATION SLEEVING, ELECTRICAL, SPECIAL PURPOSE; INSULATION SLEEVING, THERMAL; SLEEVE, MARKER, CABLE; SLEEVING, TEXTILE, ELECTRICAL; TUBING, GLASS; AND TUBING, NONMETALLIC.
CAGE Information
Code | Company |
---|---|
20999 | 3M CO ADMININISTRATIVE ELECTRONIC & |
Federal Supply Class
Title
ELECTRICAL INSULATORS AND INSULA
Inclusions:
INCLUDES TUBE, KNOB, CLEAT, STRAIN, AND STANDOFF INSULATORS; FEED THRU INSULATORS; BEAD INSULATORS; VARNISH CAMBRIC TAPE; FRICTION TAPE.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABJH | TEMP RATING | -55.0 DEG CELSIUS AND 250.0 DEG CELSIUS |
HUES | COLOR | BLACK |
CQBC | MINIMUM TENSILE STRENGTH | 2200 POUNDS PER SQUARE INCH |
STYL | STYLE DESIGNATOR | SHRINKABLE |
FLEX | FLEXIBILITY | FLEXIBLE |
AFZN | RECOVERED WALL THICKNESS | 0.042 INCHES MINIMUM AND 0.058 INCHES MAXIMUM |
MATL | MATERIAL | PLASTIC, POLYOLEFIN, RT-876, RAYCLAD TUBES INC |
AGAU | HEAT SHRINKAGE RATING IN PERCENT | 50.0 |
ADZC | ENVIRONMENTAL PROTECTION | FLAME RESISTANT AND MILDEW RESISTANT AND CORROSION RESISTANT AND SOLVENT RESISTANT |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
UKBG | DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS | 800.0 VOLTS PER MIL /0.001 INCH/ |
AFZM | RECOVERED INSIDE DIAMETER | 1.500 INCHES MAXIMUM |
AFZL | EXPANDED INSIDE DIAMETER | 3.000 NOMINAL MILS |